Exercise 1

With copper Kα radiation (λ = 1.5418 Å), a first-order reflection appears at θ = 20.0°. What distance separates the planes that produce it? At what angle would it appear with molybdenum radiation (λ = 0.7107 Å)?

With n = 1, d = λ/(2 sin θ) = 1.5418/(2 × 0.3420) = 2.254 Å. With molybdenum, sin θ = 0.7107/(2 × 2.254) = 0.1577, so θ = 9.07°. Shorter-wavelength radiation compresses the diffraction pattern towards smaller angles.

Exercise 2

In an X-ray structure, the mean C–H distance is 0.96 Å, whereas neutron diffraction gives 1.09 Å for the same bonds. What causes the difference? Does the same happen with C–C bonds?

X-rays are scattered by electrons, not by nuclei. Hydrogen's single electron is pulled towards the carbon, because it forms the bond, and the electron-density maximum lies closer to the carbon than the proton does: the apparent C–H distance is shorter. Neutrons are scattered by nuclei and give the true internuclear distance. In C–C bonds the effect is negligible, because each carbon has six electrons, most of them in inner shells centred on the nucleus.

Exercise 3

The structure of a natural product C15H22O3 is refined using molybdenum radiation and gives a Flack parameter of 0.3 with an error of 0.5. Can the absolute configuration be considered determined? What would you do?

No. The value of 0.3 is compatible, within its ±0.5 error, both with 0 (correct configuration) and with 1 (inverted configuration). The molecule contains only C, H and O, and with molybdenum radiation anomalous dispersion is very weak. The solutions are to repeat the measurement with copper radiation, which increases the effect, to prepare a derivative containing a heavy atom (for example, a p-bromobenzoate ester) or to use another method, such as Mosher's or circular dichroism.