Skip to content
Course map Español

HMBC: multiple-bond correlations

HMBC (Heteronuclear Multiple Bond Correlation) correlates each hydrogen with the carbons two and three bonds away. It is the only routine experiment in which carbons without hydrogens appear, and the one that joins the fragments COSY leaves apart.

Beyond the direct bond

HSQC only sees the carbon each hydrogen is bonded to. HMBC is tuned to the small constants, 2JCH and 3JCH (2 to 10 Hz), and filters out one-bond correlations. Each spot links a hydrogen to a neighbouring carbon or a "neighbour's neighbour".

We look at ethyl crotonate again, on the same benchtop instrument. The spectrum took 69 minutes, twice as long as the HSQC, because long-range correlations are weaker.

HMBC of ethyl crotonate: 1H on the horizontal axis, 13C on the vertical axis and many correlations, including those of the carbonyl at 166 ppm
HMBC of ethyl crotonate.

Compared with the HSQC:

  1. The axes and reference spectra are the same.
  2. There are many more spots, and almost every hydrogen and carbon has several.
  3. The carbonyl (C-4, 166 ppm) appears; it has no hydrogens and did not show in the HSQC.
  4. There are no colours to distinguish CH, CH2 and CH3.

Interpretation

The ethyl group. In the HSQC, the pairings were 1.3 / 14 ppm and 4.2 / 60 ppm. In the HMBC they "cross over": the CH3 hydrogens (1.3 ppm) correlate with the CH2 carbon (60 ppm), and the CH2 hydrogens (4.2 ppm) with the CH3 carbon (14 ppm). In both cases, over two bonds.

The olefinic fragment. The CH3-1 hydrogens (1.9 ppm) correlate with both double-bond carbons: with C-2 (145 ppm), over two bonds, and with C-3 (122 ppm), over three.

The carbonyl. This is the most valuable information. C-4 (166 ppm) shows two important correlations:

  • with H-2 (7.0 ppm), over three bonds (H–C2–C3–C4);
  • with the CH2-6 hydrogens (4.2 ppm), also over three bonds, through the oxygen (H–C6–O5–C4).
HMBC of ethyl crotonate with the two carbonyl correlations circled in orange: with the hydrogen at 7.0 ppm and with the CH2 at 4.2 ppm
The carbonyl correlations, circled in orange.

These two correlations join the two spin systems that COSY left apart. The carbonyl is bonded on one side to the CH3–CH=CH fragment and on the other to the ethyl oxygen. The structure is complete.

Care in interpretation

  • Two or three bonds. HMBC does not distinguish a two-bond correlation from a three-bond one. 3J correlations are often even stronger than 2J ones. Both possibilities must be tried.
  • Missing correlations. 3JCH follows a Karplus-type relationship with the dihedral angle: if this approaches 90°, the constant is almost zero and the correlation does not appear even though the atoms are three bonds apart.
  • Four-bond correlations. They sometimes appear, weakly, especially in conjugated or aromatic systems.
  • Remnants of the direct bond. If the filter is not perfect, the one-bond correlation leaves a pair of spots separated by 1JCH (about 140–160 Hz), symmetric about the hydrogen. Some can be seen in this spectrum, for example near 60 and 122 ppm. They are not long-range correlations.

HMBC places the carbons without hydrogens and joins the fragments through carbonyls, heteroatoms and quaternary carbons. It is the piece that completes the structure.

Why HMBC cross peaks look tilted

If you look closely at the HMBC, many cross peaks are not round or aligned with the axes, but slightly tilted. The reason lies in the 1H–1H couplings. HSQC is designed so that these couplings act only during acquisition, and each cross peak splits into a multiplet only along the 1H direction (F2). In HMBC this is not so: during the evolution time t1, what evolves is a coherence that involves 1H and 13C at the same time (a “multiple-quantum” coherence), and the couplings of the hydrogen with its neighbours keep acting. The hydrogen multiplet then appears in both dimensions, and its components line up along a line that, measured in hertz, advances by the same amount in F1 as in F2. Drawn in ppm, that line looks tilted: one hertz is four times more ppm on the 13C axis (15 MHz) than on the 1H axis (60 MHz), but since the 13C scale spans 180 ppm against 9 ppm for 1H, the tilt that we see is small. In addition, HMBC is usually displayed in magnitude mode, without phase correction, which broadens and distorts the cross peaks a little.