Signal intensity: the integral
The area of each signal, its integral, is proportional to the number of hydrogens that produce it. Integrals are relative: they are adjusted to whole numbers of hydrogens with the help of the molecular formula and carry an error of 5 to 10 %. Before integrating, the solvent signals must be recognized and discarded.
Relative integrals and whole numbers
The spectrometer measures the area of each signal. Do not confuse area with height: two signals of the same area will be taller or shorter depending on their width, and the width of signals in 1H NMR varies for several reasons that will be seen throughout the course. The spectrometer draws the area as an additional step-shaped curve superimposed on the spectrum, and can make it easier to measure by printing a number next to each signal. The height of each step is proportional to the area of its signal. But it does not know how many hydrogens there are in total: it only gives relative areas. Look at these two spectra, and suppose you do not know the structures.


In the spectrum on the left, the software has assigned the value 1 to the smallest signal, and the other integrates for 1.51. Can there be one and a half hydrogens? No: the sensible thing is to multiply all the integrals by a whole number until they come close to whole numbers. Multiplying by 2 gives 2 : 3; by 4, 4 : 6, and so on.
Which is right? The molecular formula (C8H10) decides, telling us there are ten hydrogens. The signal at 7.1 ppm belongs to the hydrogens bonded to the ring, deshielded by the ring current: there are four, equivalent by symmetry. The other signal is that of the two CH3, six hydrogens that are also equivalent. The real ratio is 4 : 6.
In the spectrum on the right, the 1 : 5.88 ratio has to be multiplied by 2, giving 2 : 11.76: two aromatic hydrogens and twelve from the four methyls. But 11.76 is not a whole number. That is another detail to learn: the integral is not exact.
The precision of the integral
Integration has an intrinsic error of at least 5 %, which can reach 10 % and does not affect all signals equally. It depends on:
- The noise of the spectrum and the baseline correction.
- The closeness or overlap of the signals, which forces a decision on where one ends and another begins.
- Relaxation: if the FIDs are accumulated too quickly, nuclei that return to equilibrium more slowly give somewhat smaller signals than they should.
To integrate a spectrum, assign unity to the smallest signal and, if necessary, multiply all the areas by the whole number that brings them close to whole numbers, taking the molecular formula into account. The sum of the integrals must match the number of hydrogens in the formula.
If the spectrum is recorded carefully (with long waiting times between pulses and an internal standard of known purity), the integral can be very precise. Quantitative NMR is used to measure the purity of drugs, the proportions of the components of a mixture or the yield of a reaction without isolating the product.
The solvent signals
Now look at these two spectra. At first sight they are almost identical; the big difference is the solvent in which each substance has been dissolved.


The first thing to do when analysing a spectrum is to identify the solvent signals. They do not belong to the compound being studied and, with rare exceptions, there is no point in integrating them.
Deuterated solvents are used in NMR, in which hydrogen (1H) has been replaced by deuterium (2H), the isotope of mass 2. Deuterium has a very different gyromagnetic ratio and resonates at a very different frequency: it does not appear in the 1H spectrum. But no deuterated solvent is 100 % pure, and there is always a small residual signal from the species with one 1H. In addition, almost all of them contain some water, which gives another signal.
| Solvent | Residual signal (ppm) | Water (ppm) |
|---|---|---|
| CDCl3 | 7.26 (CHCl3) | 1.56 |
| DMSO-d6 | 2.50 (quintet) | 3.33 |
| D2O | 4.79 (HOD) | - |
| CD3OD | 3.31 (quintet) | 4.87 |
| Acetone-d6 | 2.05 (quintet) | 2.84 |
| C6D6 | 7.16 | 0.40 |
Once the solvent signals are excluded (4.79 ppm in A and 7.26 ppm in B), the two spectra are very similar. Both have a quartet and a triplet and the same integral ratio, 1 : 1.5, that is, 2 : 3. But the chemical shifts are somewhat different: 3.8 and 1.3 ppm in A; 3.5 and 1.2 ppm in B. Are they the same substance? From these two spectra alone it is very hard to say, because changing the solvent can move the signals slightly.
In fact, A is ethanol (CH3CH2OH), whose OH exchanges with the D2O and joins the HOD signal, and B is diethyl ether (CH3CH2OCH2CH3), whose two ethyl groups are equivalent. How could the doubt be resolved? Sometimes the answer lies in another technique. An infrared spectrum of the pure substances would show the broad O-H band of the alcohol at about 3300 cm−1, absent in the ether, and a mass spectrum would give very different molecular masses: 46 and 74. It would also be enough to record the ethanol in CDCl3, where its OH does appear.
NMR is the most powerful tool, but not the only one. Combined with the molecular formula, infrared and mass spectrometry, it solves almost any structure, as we will see in the topic on structure solving.
Practice
▶ A 1H spectrum solved step by step