Skip to content
Course map Español

The concept of chemical shift

The chemical shift (δ) is the position of a signal measured relative to that of a reference substance, tetramethylsilane (TMS), and divided by the frequency of the spectrometer. It is expressed in parts per million (ppm) and does not depend on the instrument: a given hydrogen appears at the same δ on an 80 MHz instrument as on a 600 MHz one.

Video: 1H NMR spectrum of ethyl acetate, shifts and integrals▶ Ethyl acetate: shifts and integrals

The trouble with hertz

In a field of 1.88 T, 1H resonates at about 80,000,000 Hz (80 MHz), as we saw in the previous topic. But the hydrogens of a molecule do not all resonate at exactly that frequency. If we irradiate 2-chloropropane, CH3CHClCH3, with a radio-frequency band a few kilohertz wide centred on 80 MHz, two signals appear, at:

  • 80,000,317.6 Hz (the CH)
  • 80,000,124.0 Hz (the two CH3)

On a more powerful instrument, of 7.05 T, 1H resonates at about 300 MHz, and the two signals appear at:

  • 300,001,191.0 Hz
  • 300,000,465.0 Hz

There are two serious problems. The numbers are unwieldy, and they also change from one instrument to another. How, then, can we compare spectra recorded on different spectrometers?

The solution: parts per million

Both problems are solved at once. First, we measure each signal relative to a reference signal that appears to the right of almost all others (we will see which one later): that leaves only the “extra hertz”, 317.6 and 124.0 Hz on the 80 MHz instrument, and 1191.0 and 465.0 Hz on the 300 MHz one. Then we divide those hertz by the spectrometer frequency in megahertz:

80 MHz (1.88 T)300 MHz (7.05 T)
CH317.6 Hz / 80 MHz = 3.97 ppm1191.0 Hz / 300 MHz = 3.97 ppm
CH3124.0 Hz / 80 MHz = 1.55 ppm465.0 Hz / 300 MHz = 1.55 ppm

Hertz divided by megahertz are millionths: parts per million. We have obtained small numbers, 3.97 and 1.55 ppm, which are also the same on both instruments.

Simulated spectrum of 2-chloropropane at 80 MHz and at 300 MHz with a hertz scale below and a ppm scale above: in hertz the CH and CH3 signals appear at 317.6 and 124.0 Hz at 80 MHz, and at 1191.0 and 465.0 Hz at 300 MHz; in ppm, always at 3.97 and 1.55
2-Chloropropane on two spectrometers: in hertz the signals move; in ppm, they do not. Notice also that at 300 MHz the multiplets take up, proportionally, much less room.

Chemical shifts in ppm, whether of 1H, 13C or any other nucleus, do not depend on the magnetic field of the instrument. This is essential for comparing spectra recorded on different spectrometers and for compiling tables of values.

Sometimes the reverse operation is useful. To go from ppm to hertz, just multiply by the spectrometer frequency in MHz. On a 600 MHz instrument (14.1 T), the signals at 3.97 and 1.55 ppm are 3.97 × 600 = 2382 Hz and 1.55 × 600 = 930 Hz from TMS: 1452 Hz apart, compared with 194 Hz on the 80 MHz instrument. That is the great advantage of strong fields: they spread the signals further apart. On the other hand, the spacing between the lines of a multiplet (the coupling constant, in Hz) does not depend on the field, which is why multiplets look narrower in ppm at high field. We will see this in the topic on coupling.

The reference: TMS

The reference signal is that of tetramethylsilane (TMS), Si(CH3)4, which is assigned δ = 0. The full definition of the chemical shift is:

δ (ppm) = (νsample − νTMS) / νspectrometer × 106

TMS is an almost ideal reference:

  • Its twelve hydrogens are equivalent and give a single sharp, intense signal, even when very little is added.
  • Silicon is less electronegative than carbon, so its hydrogens are more “shielded” than those of almost all organic compounds and appear to the right of them. That is why almost all δ values are positive.
  • It is inert, soluble in organic solvents and very volatile (it boils at 27 °C), so it is easily removed to recover the sample.

In practice, TMS is often not added and the small residual signal of the deuterated solvent, whose δ is known, is used as a secondary reference: 7.26 ppm for the CHCl3 remaining in CDCl3, for example.

The vocabulary of the scale

The δ scale is drawn increasing to the left. A signal on the left (high δ) corresponds to a deshielded hydrogen, and one on the right (low δ) to a shielded one; the next page explains why. Older texts speak of signals “downfield” (left) and “upfield” (right), a legacy of the instruments that swept the magnetic field at a fixed frequency: a deshielded hydrogen comes into resonance sooner, at a lower applied field. The “field” in these expressions is therefore the applied field, not the one the nucleus feels; we will come back to this when discussing the ring current.

The regions of the spectrum

The hydrogens of each type of group appear in characteristic regions of the scale, which are worth learning as soon as possible:

General chemical shift regions in 1H and 13C: from right to left, aliphatic, aliphatic bonded to heteroatoms, alkynes, alkenes, aromatics, aldehydes and acids
General chemical shift regions for 1H (top) and 13C (bottom).
Type of hydrogenδ (ppm)
Alkyl: CH3, CH2, CH0.9-1.8
Next to a double bond, an aromatic ring or a carbonyl (CH3C=C, ArCH3, CH3CO)1.6-2.7
Terminal alkyne, C≡C-H1.8-3.1
Next to nitrogen, CH-N2.2-3.0
Next to halogen, CH-Cl, CH-Br2.7-4.2
Next to oxygen, CH-O (alcohols, ethers, esters)3.3-4.5
Alkene, C=C-H4.5-6.5
Aromatic, Ar-H6.5-8.5
Aldehyde, CHO9-10
Carboxylic acid, COOH10-13
OH of alcohols and NH of amines0.5-5, variable

For example, in ethyl acetate, CH3COOCH2CH3, from the video, the CH3 bonded to the carbonyl appears at 2.0 ppm, the OCH2 at 4.1 ppm and the ethyl CH3 at 1.3 ppm. The values in the table are a guide; the factors that determine them are studied on the next page.