Skip to content
Course map Español

Monitoring reactions by spectroscopy

The techniques in this course are not only for identifying the final product. They also make it possible to follow a reaction as it happens: to know when it has finished, to measure its rate, to check that no by-products form and, sometimes, to see the intermediates it passes through. This section reviews what each spectroscopy contributes to that task.

Why and how a reaction is monitored

Monitoring a reaction makes it possible to stop it at the right moment, before the product decomposes or by-products appear; to optimize the conditions (temperature, catalyst, solvent); to measure rate constants and reaction orders; and to detect intermediates that support or rule out a mechanism. In industry, the continuous control of processes with spectroscopic probes is known as process analytical technology (PAT).

There are two ways of doing it:

  • Off-line: aliquots are taken at intervals, the reaction is stopped in them (by cooling, dilution or neutralization) and they are analysed by thin-layer chromatography, HPLC, NMR or mass spectrometry. It is simple, but each sample disturbs the reaction and unstable intermediates do not survive the work-up.
  • On-line or in situ: a probe inside the reactor, a cell through which the mixture flows, or the NMR tube itself records spectra continuously without touching the reaction.

Thin-layer chromatography is still the quickest way to know whether any starting material is left, but it gives neither amounts nor structures. Spectroscopic techniques give both, provided three conditions are met: there must be a characteristic signal of a reactant or a product that does not overlap with the others; that signal must be proportional to the concentration; and each spectrum must be recorded in a time that is short compared with that of the reaction.

In situ infrared spectroscopy

An ATR (attenuated total reflection) probe with a diamond crystal at its tip is immersed in the reaction mixture and records a spectrum every few seconds (the principle of ATR is explained in The IR spectrum). The solvent spectrum is subtracted and the absorbance of the chosen bands is followed; by the Beer–Lambert law, it is proportional to the concentration.

The key is to choose bands in clean regions of the spectrum. A classic example is the formation of a urethane from an isocyanate and an alcohol, the reaction on which polyurethanes are based: the strong N=C=O band, near 2270 cm−1, lies in a region where almost nothing else absorbs and decreases as the reaction proceeds, while the urethane C=O band (1725 cm−1) and the N–H bending band (1530 cm−1) grow. The aromatic ring bands, which do not change, serve as an internal reference.

Successive IR spectra of the reaction of an isocyanate with an alcohol between 2400 and 1450 cm⁻¹, from 0 to 80 minutes: the N=C=O band at 2270 cm⁻¹ decreases and the urethane C=O band at 1725 and the N–H band at 1530 cm⁻¹ grow; on the right, the absorbance at 2270 cm⁻¹ decays exponentially and the absorbance at 1725 cm⁻¹ grows with time
ATR-IR monitoring of the reaction of an aromatic isocyanate with an excess of alcohol (simulated). On the right, the absorbance of each band against time.

In situ IR is widely used in process laboratories: to check that the formation of a Grignard reagent has started before adding more of the halide (a safety issue), to follow hydrogenations, acylations or polymerizations, and to detect unstable species that would not survive sampling. Raman spectroscopy, with fibre-optic probes, is its complement: water hardly interferes with it, and it gives strong bands for symmetrical bonds, such as C=C, S–S or C≡C, which are weak in the IR.

UV-visible spectroscopy

If a reactant or a product has a chromophore that changes during the reaction (see Electronic transitions and chromophores), UV-visible spectroscopy is the most sensitive and simplest technique: a micromolar concentration is enough, the cell is thermostatted in the spectrophotometer itself, and the absorbance gives the concentration directly, A = ε c l. With a stopped-flow instrument, which mixes the reactants in milliseconds and drives them into the measuring cell, reactions that are over in less than a second can be studied.

A widely used example is the hydrolysis of p-nitrophenyl acetate in a basic buffer. The ester absorbs near 270 nm and is colourless; the product, the p-nitrophenolate anion, is yellow and absorbs at 400 nm with ε ≈ 18 000 M−1 cm−1. This reaction is the basis of many esterase and lipase activity assays.

Successive UV-visible spectra of the hydrolysis of p-nitrophenyl acetate between 240 and 480 nm, from 0 to 70 minutes: the ester band at 268 nm decreases, the p-nitrophenolate band at 400 nm grows and all the curves cross at an isosbestic point near 325 nm; on the right, the absorbance at 400 nm grows with time to a constant value
Hydrolysis of p-nitrophenyl acetate (5 × 10−5 M, 1 cm cell) followed by UV-visible spectroscopy (simulated). All the spectra pass through an isosbestic point.

All the spectra cross at one point. It is an isosbestic point: the wavelength at which the reactant and the product have the same absorption coefficient, so that the absorbance does not change as one turns into the other. Spectra that pass cleanly through an isosbestic point show that the reaction converts one species into another with a constant stoichiometry, without any intermediate building up. If the point blurs or shifts, a third species appears: an intermediate that accumulates or a side reaction.

Its limitation is the scarce structural information: the bands are broad and overlap, and the technique does not say what is absorbing.

Nuclear magnetic resonance

NMR is the most informative technique, because each species in the mixture gives its own signals and the integrals are proportional to the number of nuclei without the need to calibrate the response of each compound (see The intensity of the signals: the integral). By adding a known amount of an internal standard, inert and with an isolated signal, the concentration of any species is calculated directly:

[X] = [standard] × (IX / nX) / (Istandard / nstandard), where I is the integral and n the number of hydrogens in each signal.

For the integrals to be quantitative, the time between pulses must allow all the nuclei to relax (about five times the longest T1), and for each spectrum to be a "snapshot" of the reaction, few scans are recorded. The reaction is run in the tube itself, inside the magnet and at a controlled temperature, and the spectrometer automatically records a series of spectra at fixed intervals.

As an example, the acid-catalysed hydrolysis of methyl acetate in D2O, with dimethyl sulfone, (CH3)2SO2, as the standard (a six-hydrogen singlet at 3.14 ppm):

CH3CO2CH3 + D2O → CH3CO2D + CH3OD

¹H spectra of the hydrolysis of methyl acetate at 0, 30, 60, 120 and 240 minutes: the ester OCH₃ singlet at 3.69 ppm decreases, the methanol CH₃ at 3.35 ppm grows, the dimethyl sulfone standard at 3.14 ppm does not change, and in the 2.1 ppm region the ester CH₃CO at 2.11 ppm turns into that of acetic acid at 2.07 ppm
Hydrolysis of methyl acetate (50 mM) in D2O with DCl, followed by 1H NMR at 400 MHz with dimethyl sulfone (10 mM) as the internal standard (simulated).

The ester OCH3 signal (3.69 ppm) decreases and the methanol CH3 signal (3.35 ppm) grows, while that of the standard stays constant; the same happens with the acetyl groups of the ester (2.11 ppm) and of the acid (2.07 ppm). The concentrations are calculated from the integrals and plotted against time. As water is in large excess, the reaction is pseudo-first order: ln([E]/[E]0) = −kt, and a plot of the logarithm against time is a straight line of slope −k. The sum [ester] + [methanol] stays constant, which confirms that no other product forms: the mass balance is a check that only a technique that sees all the species at once can provide.

On the left, the concentration of methyl acetate, which decays from 50 to 3 mM, and of methanol, which grows to 47 mM, against time from 0 to 240 minutes; on the right, ln([E]/[E]₀) against time is a straight line of slope −0.0116 min⁻¹, with a half-life of 60 minutes
Concentrations obtained from the integrals and first-order plot (simulated data).

Other possibilities of NMR in reaction monitoring:

  • Detection of intermediates: signals appear that grow and then disappear. 19F and 31P NMR (¹⁹F and ³¹P NMR) are especially useful for this: the spectra are simple, the solvent gives no signal and the shifts are very sensitive to structural changes. At low temperature, intermediates that last milliseconds at room temperature can live for hours: this is how the oxaphosphetane of the Wittig reaction, described in that same section, was observed by 31P.
  • Flow NMR: the reaction mixture, in a flask or a reactor of any size and with non-deuterated solvents, flows through a cell inside the magnet, and the solvent signals are removed with suppression sequences.
  • Benchtop spectrometers: with 40 to 80 MHz permanent magnets (see NMR spectrometers and techniques), they can be placed next to the fume hood and connected to the reactor.

This application should not be confused with dynamic NMR. There, reversible processes at equilibrium, such as rotations or inversions, are studied; they are so fast that they are measured from the shape of the signals in a single spectrum. Here the reaction is slow and turns some molecules into others, and its course is followed in successive spectra.

Mass spectrometry

Electrospray ionization (ESI, see Ionization methods) transfers the ions present in solution into the gas phase without fragmenting them. By feeding a small stream of the reaction mixture directly into the instrument, charged intermediates can be detected at very low concentrations, for example metal complexes in a catalytic cycle or iminium ions in organocatalysis. The exact mass and the isotope pattern give their formula.

Direct quantification is difficult, because the ionization efficiency varies greatly from one species to another. To follow the progress of a reaction, mass spectrometry is coupled to chromatography (LC-MS or GC-MS) and aliquots are analysed: the chromatography separates and quantifies the components, and the mass spectrum identifies each peak, including minor by-products.

Choosing the technique

TechniqueWhat is observedTypical concentrationStructural informationUsual mode
IR (ATR)Functional groupsmMMediumIn situ probe
RamanSymmetrical bonds; aqueous mediamMMediumFibre-optic probe
UV-visibleChromophoresμMLowCell, probe or stopped-flow
NMRAll species with 1H (or 19F, 31P)mMVery high; quantitative without calibrationNMR tube or flow cell
Mass spectrometry (ESI)Ions; charged intermediatesnM–μMMass and formulaDirect infusion or LC-MS of aliquots

In practice, the techniques are combined: UV-visible or IR give kinetic curves with many points, NMR identifies and quantifies all the species, and mass spectrometry detects what is present at concentrations too low for the others.